Refrigeration air conditioning equipment usually reduces the humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air (much like an ice-cold drink will condense water on the outside of a glass), sending the water to a drain and removing water vapor from the cooled space and lowering the relative humidity. Since humans perspire to provide natural cooling by the evaporation of perspiration from the skin, drier air (up to a point) improves the comfort provided. The comfort air conditioner is designed to create a 40% to 60% relative humidity in the occupied space. In food retailing establishments, large open chiller cabinets act as highly effective air dehumidifying units.
A specific type of air conditioner that is used only for dehumidifying is called a dehumidifier. A dehumidifier is different from a regular air conditioner in that both the evaporator and condenser coils are placed in the same air path, and the entire unit is placed in the environment that is intended to be conditioned (in this case dehumidified), rather than requiring the condenser coil to be outdoors. Having the condenser coil in the same air path as the evaporator coil produces warm, dehumidified air. The evaporator (cold) coil is placed first in the air path, dehumidifying the air exactly as a regular air conditioner does. The air next passes over the condenser coil re-warming the now dehumidified air. Note that the terms "condenser coil" and "evaporator coil" do not refer to the behavior of water in the air as it passes over each coil; instead they refer to the phases of the refrigeration cycle. Having the condenser coil in the main air path rather than in a separate, outdoor air path (as in a regular air conditioner) results in two consequences—the output air is warm rather than cold, and the unit is able to be placed anywhere in the environment to be conditioned, without a need to have the condenser outdoors.
Unlike a regular air conditioner, a dehumidifier will actually heat a room just as an electric heater that draws the same amount of power (watts) as the dehumidifier. A regular air conditioner transfers energy out of the room by means of the condensor coil, which is outside the room (outdoors). This is a thermodynamic system where the room serves as the system and energy is transferred out of the system. Conversely with a dehumidifier, no energy is transferred out of the thermodynamic system (room) because the air conditioning unit (dehumidifier) is entirely inside the room. Therefore all of the power consumed by the dehumidifier is energy that is input into the thermodynamic system (the room), and remains in the room (as heat). In addition, if the condensed water has been removed from the room, the amount of heat needed to boil that water has been added to the room. This is the inverse of adding water to the room with an evaporative cooler.
Dehumidifiers are commonly used in cold, damp climates to prevent mold growth indoors, especially in basements. They are also sometimes used in hot, humid climates for comfort because they reduce the humidity which causes discomfort (just as a regular air conditioner, but without cooling the room). They are also used to protect sensitive equipment from the adverse effects of excessive humidity in tropical countries.
The engineering of physical and thermodynamic properties of gas-vapor mixtures is named Psychrometrics.
http://en.wikipedia.org
Tags:
air conditioning ,humidity ,relative humidity ,moisture ,humidity levels ,heat pump ,refrigerant ,high humidity ,ventilation ,thermostat ,refrigeration cycle ,refrigerants ,products ,indoor air ,humidity control ,humidifiers ,evaporator coil ,evaporation ,equipment ,energy ,efficiency ,the cooling ,respiratory infections ,proper humidity ,moisture levels ,levels ,lennox ,latent heat ,indoor humidity ,indoor air quality ,hvac system ,humidity increases ,humidifier ,heating systems ,evaporator ,energy efficiency ,ductwork ,dry air ,delicate balance ,dehumidifiers ,dehumidifier ,condenser coils ,condenser ,compressor ,cold air ,climate ,capacity ,blower ,atmosphere ,asthma ,ashrae ,ammonia ,airflow ,air-conditioning system ,air temperature ,air path ,air conditioning systems ,air conditioning system ,air conditioners ,air conditioner